Veris AG01E (CO Sensor, 5% Accuracy) | eBay

Find many great new used options and get the best deals for Veris AG01E (CO Sensor, 5% Accuracy) at the best online prices at eBay! Free shipping for many products!


Wall CO NO2 Sensors

AG01 CO, Sensor Module, GWN series, 0200ppm range, setpoints 25 or 35, 180: AG02 NO2,SensorMod,GWN,015ppm range,setpoint 1ppm (fixed) ,3ppm (fixed) AG01E CO, Sensor Module, GWN series, 0500ppm range, 5% accuracy: GWN1XX Gas,Platform, Wall Mount, Hi/Lo/End of Life, relay only (requires sensor module) GWNMXX Gas,Platform, Wall Mount, Hi/Lo/End of Life, 4 to …


Veris AG01 (CO Sensor, 3% Accuracy) | eBay

Veris AG01 (CO Sensor, 3% Accuracy) | Business Industrial, Industrial Automation Motion Controls, Sensors | eBay!


Installation Guide Accessories Energy Sensors and ...

The AG01 carbon monoxide (CO) sensing element is designed to work with the Veris GWN Series gas platform unit to provide accurate monitoring of CO levels. Common sources of CO include automobile exhaust from gasoline engines, gasoline powered furnaces, gasoline powered water heaters, and gasoline generators. The sensor is calibrated at the factory, so no field calibration is needed. The …


GWN1XX | Veris Industries | Gas Specialty Sensors Kele

AG01. Veris Industries. CARBON MONOXIDE SENSORCOMPONET. add to cart . Top Sellers. KCDWV. Kele. CO2 SENSOR WALL VDC OUT. add to cart . CDAW. Kele. CO2 SENSOR 420MA. add to cart . KCDDV. Kele. CO2 SENSOR DUCT VDC OUT. add to cart . T8100. Amphenol Advanced Sensors. CO2 WALLMNT SNSR NO DISPLAY WHITE . add to cart . KCDDA. Kele. CO2 SENSOR …


AG01 Veris AG01 Carbon Monoxide (CO) Sensing Element ...

The AG01 carbon monoxide (CO) sensing element is designed to work with the Veris GWN Series gas platform unit to provide accurate monitoring of CO levels. Common sources of CO include automobile exhaust from gasoline engines, gasoline powered furnaces, gasoline powered water heaters, and gasoline generators. The sensor is calibrated at the factory, so no field calibration is needed. The …


Air uali Gas Detectio GWN Series SPECIFICATIONS

AG01 CO Sensor AG01E CO Sensor AG02 NO 2 Sensor SENSOR TYPE Electrochemical Electrochemical Electrochemical MEASUREMENT RANGE 0 to 300 ppm 0 to 500 ppm 0 to 15 ppm ACCURACY ±3% of range ±5% of range ±5% of range at 25 °C ANALOG OUTPUT SCALING 0 to 200 ppm 0to 200 ppm 0 to 15 ppm RESOLUTION 1 ppm 1 ppm ppm SENSOR WARRANTY 2 years …


AG01 CO, Sensor Module, GWN series, 0200ppm range, set ...

AG01 CO, Sensor Module, GWN series, 0200ppm range, setpoints 25 or 35, 180, 3% accuracy ... CO Sensors; Gas Calibration; Duct Smoke Detectors; Accessories ; CO2 Sensors Duct Mount; CO2 Sensors Wall Mount; Alarms Indication. LoopPowered Indicators; Tower Lights; Alarm Indication Stations; Strobes Horns ; Emergency Operator Stations; Wall Displays; Automated Logic …


Veris AG01 | Sensor Accessories and Replacements ...

Veris AG01 : Electrochemical CO sensor, 3% accuracy, 0 to 300 ppm, 5Year Warranty FREE SHIPPING on orders over 150. Call our sales team for a quote. 8887398400 ...


| Veris Industries AG01 | Gas Specialty Sensors ...

AG01 | Veris Industries | Gas Specialty Sensors CO Sensor 0200 ppm, Enables Relay Contacts When Co Level Is Above 25ppm Or 35 ppm And Also When The Co …


GWNP Communication Microprocessor Energy Sensors and ...

CO Sensor AG01 CO Sensor AG02 NO 2 Sensor SENSOR TYPE Electrochemical Electrochemical Electrochemical CO: Electrochemical NO 2: Electrochemical Nondispersive infrared Nondispersive infrared MEASUREMENT RANGE 0 to 300 ppm 0 to 500 ppm 0 to 15 ppm CO: 0 to 500 ppm NO 2: 0 to 20 ppm 0 to 2000 ppm 0 to 2000 ppm ACCURACY ±3% of range ±5% of range ±5% of range at 25 °C …


GWNMXX | Veris Industries | Gas Specialty Sensors Kele

AG01. Veris Industries. CARBON MONOXIDE SENSORCOMPONET. add to cart . AG02. Veris Industries. NITROGEN DIOXIDE SENSORCOMPONET. add to cart . AFBUPSX1. Belimo. VALVE ACT/SR/24 TO 240V (UP)/ON/ add to cart . AG01E. Veris Industries. CARBON MONOXIDE SENSORCOMPONET. add to cart . Top Sellers. KCDWV. Kele. CO2 SENSOR WALL VDC OUT. add to cart . …


Veris AG01 Gas Sensor Module | Veris Gas Detection AG01

The AG01 carbon monoxide (CO) sensing element is designed to work with the Veris GWN series gas platform unit to provide accurate monitoring of CO levels. Common …


Veris AG01E Gas Sensor Module | Veris Gas Detection AG01E

The AG01E carbon monoxide (CO) sensing element is designed to work with the Veris GWN series gas platform unit to provide monitoring of CO levels. Common sources of CO include automobile exhaust from gasoline engines, gasoline powered furnaces, gasoline powered water heaters, and gasoline generators. The sensor is calibrated at the factory, so no field calibration is needed. The AG01E is ...


AG01 by VERIS Buy or Repair at Radwell

AG01 Sensors Switches from VERIS 2Year Warranty CARBON MONOXIDE SENSOR MODULE, 0200 PPM, 3% , ACC, HUMIDITY RANGE: 0 TO 90% RH, TEMPERATURE RANGE: 4~122 DEG F


GWN Series SPECIFICATIONS

AG01 CO Sensor AG01E CO Sensor ” (15 mm) ” (113 mm) ” (70 mm) ” (30 mm) ” (27 mm) ” (42 mm) ” (83 mm) Power Supply Control System Relay + – Common – Gas Sensor Input* Common High Setpoint End of Life Low Setpoint * Not available on relay only models. AG02 NO 2 Sensor X GWN Series Sensor Type Electrochemical Electrochemical Electrochemical Measurement ...


Gas Detection | Veris

Veris AG01 Gas Sensor Module +/3% Accuracy CO Sensor, 0 to 300 ppm. Brand: Veris; Veris Part: AG01; Est. Shipping Date: Your Price: Qty Add To Cart; Add to My Favorites . Select Item; Branch Availability ×. Branch Name Est. Shipping Date; No Records Found: Compare. Veris AG04 Gas Sensor Module +/5% Accuracy Combination CO and NO2 Sensor, 0 to 500 ppm CO, 0 More... Brand: Veris; …


AG01 Veris Industries Gas Sensor, Carbon Monoxide (CO ...

Find AG01 and other Veris Industries HVAC products at // AG01 Veris Industries Gas Sensor, Carbon Monoxide (CO), 300 ppm in Air, For GWN Series Platform


Installation Guide Accessories

The AG01 carbon monoxide (CO) sensing element is designed to work with the Veris GWN Series gas platform unit to provide accurate monitoring of CO levels. Common sources of CO include automobile exhaust from gasoline engines, gasoline powered furnaces, gasoline powered water heaters, and gasoline generators. The sensor is calibrated at the factory, so no field calibration is needed. The …


Air uali Gas Detectio Gas Platform for Gas Sensors GWN Series

AG01 CO Sensor AG01E CO Sensor AG02 NO 2 Sensor SENSOR TYPE Electrochemical Electrochemical Electrochemical MEASUREMENT RANGE 0 to 300 ppm 0 to 500 ppm 0 to 15 ppm ACCURACY ±3% of range ±5% of range ±5% of range at 25 °C ANALOG OUTPUT SCALING 0 to 200 ppm 0 to 200 ppm 0 to 15 ppm RESOLUTION 1 ppm 1 ppm ppm SENSOR WARRANTY 2 years …


GWMXS by VERIS Buy or Repair at Radwell

GWMXS Sensors Switches from VERIS 2Year Warranty, Radwell Repairs POS REPL AG01, CARBON MONOXIDE SENSOR 0200PPM 250MA 24V WALL MT


Veris AG01 Gas Sensor Module

The AG01 carbon monoxide (CO) sensing element is designed to work with the Veris GWN series gas platform unit to provide accurate monitoring of CO levels. Common sources of CO include automobile exhaust from gasoline engines, gasoline powered furnaces, gasoline powered water heaters, and gasoline generators. The sensor is calibrated at the factory, so no field calibration is needed. The …


| Veris GWN Series | CO sensors

ag01 : carbon monoxide sensorcomponet only 0200 ppm: : : ag01e : carbon monoxide sensorcomponet only 0500 ppm: : : ag02 : nitrogen dioxide sensorcomponet only 015 ppm: : : ag04 : carbon monoxide co and nitrogen dioxide no2 sensor


GWN Series 5 SPECIFICATIONS

AG01 CO Sensor. CO sources include exhaust from gasoline engines, gasoline powered furnaces, gasoline powered water heaters, gasoline generators AG02 NO 2 Sensor. NO 2 sources include exhaust from diesel engines and diesel powered generators GWN* Output V able,select ield = F 05/010VDC with relay M = 420mA with relay 1 = Relay only X ORDERING INFORMATION AG01 CO Sensor …


Air uali Gas Detectio Protocol Communications Gas Platform ...

AG01 CO Sensor AG01E CO Sensor AG02 NO 2 Sensor SENSOR TYPE Electrochemical Electrochemical Electrochemical MEASUREMENT RANGE 0 to 300 ppm 0 to 500 ppm 0 to 15 ppm ACCURACY ±3% of range ±5% of range ±5% of range at 25 °C ANALOG OUTPUT SCALING 0 to 200 ppm 0 to 200 ppm 0 to 15 ppm RESOLUTION 1 ppm 1 ppm ppm SENSOR WARRANTY 2 years …


Gas Specialty Sensors CO Control Products

AG01 Veris Industries CO/No2 CO, Sensor Module, GWN series, 0200ppm range, setpoints 25 or 35, 180, 3% accuracy Add to cart Details ...